New Generation
Heavy Duty Axial Roof Unit
- Robust, heavy duty construction.
- New Generation downflow supply air units can also be supplied.
- Adjustable pitch impellers provide performances to suit a wide range of applications.
- Impellers can be GRP, aluminium, nylon or anti-static to suit the application, GRP is standard.
- Shutters are a standard component for the RVE and RSS models and are an optional extra for the RDE units.
- Can be mounted at angles up to 30°.
- All standard motors are speed-controllable using variable speed drives.
- Can be used for free intake and ducted applications.
- Multi-speed motors, as well as motors to meet Ex d, Ex e, Ex nA and Ex tD standards can be supplied.
SKU: EFAP-38
Got a question about this product?
Email us or call us on +603 7846 0340 (Malaysia) or +91 33-24988126 (India)
Compatible Accessories
Overview
The heavy duty New Generation Series of axial roof units has been designed for a wide range of free intake and ducted applications. These exhaust fans are suitable for a wide range of commercial and industrial applications for handling clean air through to smoke-spill. There are 9 sizes in the series extending from 315 to 1250mm diameter.
- Product Overview
Downloads
Features and Benefits
Smoke-Spill Application
The New Generation RSS Series of smoke-spill fans has been fully tested to meet the air performance and high temperature requirements of Standards AS/NZS1668.1:1998 and AS4429:1999.
Discharge Damper Fail-open Latching
An additional requirement of AS/NZS1668.1:1998 with respect to un-sprinklered buildings (300°C for 30mins) requires dampers to fail-open during smoke spill operation. The fail-open discharge damper latches come in two forms; the first being a manual release type requiring manual closing after the fan has been run. The second design, an electro-mechanical type permits the shutter latch to release and close automatically after the fan stops. For advice on smoke-spill wiring requirements refer to AS/ NZS1668.1:1998.
Weather Resistance
Mushroom cowls limit water ingress in a range of weather conditions.
Protection
Thermistors can be provided on all motors except when standards specifically exclude their use.
Testing
All units tested to BS848:Part 1, 1980 (airside performance) and BS848:Part 2, 1985 (sound performance).
Additional Information
Accurate selections, including comprehensive Noise Data, can be obtained from your local Elta Fans office or from our Product Selection Program. Refer to Elta Fans for performances at speeds other than shown. When shutters are fitted ensure the roof unit is mounted with the shutter spindle pointing down the roof. When shutters are fitted to the RDE models derate the performance by 15-20%. Where prevailing winds are high we recommend the fitting of Magloks®. For capacities greater than shown for the New Generation Series refer to the HC and SS series.
Specification
Construction
Galvanised steel bases; cowls/wind bands are of plastic, fibreglass or galvanised steel. The RVE and RSS models are all steel construction. Impeller blades can be GRP, aluminium, nylon or anti-static to suit the application. GRP is standard.
Motor
The fans are built with squirrel cage induction motors with sealed for life ball bearings. Motors to suit a wide range of voltages and frequencies can be supplied. Motors with 2-speed windings, or to meet Ex d, Ex e, Ex nA and Ex tD Standards, can be supplied. When fans are required for non-standard air applications this must be nominated at the time of enquiry.
Control
Speed controllable using variable speed drives.
Typical Applications
Airport Terminals
Airport TerminalsBanks
BanksBowling Alleys
Bowling AlleysCall Centres
Call CentresCanteens and Food Courts
Canteens and Food CourtsCar Showrooms
Car ShowroomsCare and Nursing Homes
Care and Nursing HomesCinemas
CinemasColleges and Universities
Colleges and UniversitiesCommercial Kitchens
Commercial KitchensDark Rooms
Dark RoomsDental Surgeries
Dental SurgeriesDepartmental Stores
Departmental StoresFast Food Outlets
Fast Food OutletsFire and Police Stations
Fire and Police StationsGo Karting Tracks
Go Karting TracksGovernment Buildings
Government BuildingsGyms
GymsHospitals and Hospices
Hospitals and HospicesIce Rinks
Ice RinksIndoor Play Centres
Indoor Play CentresLaboratories
LaboratoriesLaundrettes and Dry Cleaners
Laundrettes and Dry CleanersLaw Courts
Law CourtsLibraries and Archives
Libraries and ArchivesMobile Classrooms
Mobile ClassroomsMortuaries
MortuariesMuseums and Galleries
Museums and GalleriesNail and Beauty Salons
Nail and Beauty SalonsNurseries
NurseriesOffice Buildings
Office BuildingsOperating and Mobile Theatres
Operating and Mobile TheatresPetrol Stations
Petrol StationsPharmacies
PharmaciesPlaces of Worship
Places of WorshipPortable and Temporary Offices
Portable and Temporary OfficesPrisons and Detention Centres
Prisons and Detention CentresRestaurants and Bars
Restaurants and BarsSchools
SchoolsShopping Centres
Shopping CentresSpas
SpasSports Centres
Sports CentresStadiums and Arenas
Stadiums and ArenasStudent Accommodation
Student AccommodationSupermarkets
SupermarketsSwimming Pools
Swimming PoolsTelecoms Buildings
Telecoms BuildingsTheatres
TheatresTheme Parks
Theme ParksTown Halls and Community Centres
Town Halls and Community CentresTrain and Bus Stations
Train and Bus StationsTV and Recording Studios
TV and Recording StudiosVeterinary Clinics
Veterinary ClinicsInterested? Make an Enquiry
Customers Also Viewed
EC Sensors – Combined CO2, Humidity And Temperature Sensor
View Product